Description
FLEXI-DIP Gauging Tapes (Restricted and Open) Restricted and Open Gauging Tapes provide a convenient and accurate means for measuring ullage, product temperature and the oil-water interface. The units are configured to operate in the trimode, bimode, interface or temperature mode. Each instrument is designed to maximize ease of use. A single penetration of each tank can provide comprehensive data about internal tank conditions. When the electronic probe senses hydrocarbon, a steady tone is heard; when sensing water, it emits an intermittent tone. Temperature is shown on an LED display in the hub of the instrument.
Specifications
Accuracy | |
>of Tape | +/- 1/8″ (+/- 3mm), +/- 0.01% of F.S. tape LGT (F.S. = Full Scale). |
>of Temperature Display | +/- 0.5° F (+/- 0.3° C) +/- 1 digit error. |
>of Calibration Range | 32° F (0° C) to 176° F (80° C). |
>of Probe | For dryness to within 3/8 inch (10mm) of bottom |
Ambient Temperature Limits | |
>LCD | same as above. |
>Sensor | same as above. |
Application: | |
>Open gauging | (“O” type) (Safe product vapors only). |
>Restricted gauging | (“R” type) via MMC vapor-control valve. |
Battery | 9-Volt Eveready # 522 or Mallory MN1604. |
Operation | U-Ullage, I-Interface (oil/water), T-Temperature. |
Tape Length | Tape Length |
>Dual-Marked | 50 ft. (15m), 75 ft. (25m), 100 ft. (30m), 120 ft. (37m),165 ft. (50m). |
>Single-Sided | 30m, 100 ft. engineering scale (ft., 1/10 ft., 1/100 ft.) |
Typical Weights | >50 ft/15m – “R” 8lbs (3.6kg) “F” 7 lbs. (3.2kg).
>100 ft/30m – “R” 9lbs (4.1 kg) “F” 8lbs. (3.6kg). >165 ft/50m – “R” 11 lbs (5 kg) “F” 10 lbs. (4.5 kg). |
Reviews